Your cart is currently empty!
285-Series Circuit Breaker – Surface Mount 120A
Drop in replacement for 185-Series Circuit Breakers Visible reset lever shows open condition Ignition protected – Safe for installation aboard gasoline powered boats Meets SAE J1171 external ignition protection requirements Weather Resistant Combines switching and circuit breaker function into one unit* “Trip Free” – cannot be held closed after trip * Do not use as a switch where high inrush currents are expected.
Description
Specifications
Amperage
120A
Maximum Voltage
48V DC
Mounting
Surface Mount
Circuit Breaker Type
Thermally responsive Bi-metal blade
Terminal Stud Torque
50 in-lb (5.65 Nm)
Interrupt Capacity*
3000A @ 48V**
Minimum Operating Temperature
-40° C
Maximum Operating Temperature
85° C
Circuit Breaker Class
Type III – switchable/manual reset – trip free
Terminal Stud
M6 (accepts 1/4″ Ring Terminal)
Weight
0.50lb (0.23 kg)
*The fault current that a device, normally a fuse or circuit breaker is capable of breaking without damage.
**Achieved using SAE J1625